4
460/480 V Class (1 ~ 30HP)
Model Number
(SV xxx iS5 - 4)
008
015
022
037
055
075
110
150
185
220
HP
1
2
3
5
7.5
10
15
20
25
30
Motor
Rating
1
kW
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
Capacity
2
[kVA]
1.9
3.0
4.5
6.1
9.1
12.2
18.3
22.9
29.7
34.3
FLA [A]
2.5
4
6
8
12
16
24
30
39
45
Frequency
0 ~ 400 Hz (Sensorless Vector Control: 0 ~ 300Hz, Sensored Vector Control: 0 ~ 120 Hz)
Output
Ratings
Voltage
380 ~ 460 V, 380 ~ 480 V
3
Voltage
3 Phase, 380 ~ 460 V (
±
10 %), 380 ~ 480 V (
±
10 %) (Special type available from ‘2004)
5
Input
Ratings
Frequency
50 ~ 60 Hz (
±
5 %)
Braking Circuit
On Board
On Board
Optional
(DB Resistor)
Optional (DB Resistor)
Max. Braking
Torque
100%
100%
100%
Max. Continuous
Baking Time
5 seconds
5 seconds
15 seconds
Dynamic
Braking
4
Max. Duty
3 % ED
2 % ED
20%
Continuous
10 % ED
Weight [kg]
4.7
4.7
4.8
4.9
7.7
7.7
13.9
14.4
20
20
460/480 V Class (40~100HP)
Model Number
(SV xxx iS5 - 4)
300
370
450
550
750
HP
40
50
60
75
100
Motor
Rating
1
kW
30
37
45
55
75
Capacity
2
[kVA]
45
56
68
82
100
FLA [A]
61
75
91
110
152
Frequency
0 ~ 400 Hz (Sensorless Vector Control: 0 ~ 300Hz, Sensored Vector Control: 0 ~ 120 Hz)
Output
Ratings
Voltage
380 ~ 460 V, 380 ~ 480 V
3
Voltage
3 Phase, 380 ~ 460 V (
±
10 %), 380 ~ 480 V(
±
10 %) (Special type available from ‘2004)
6
Input
Ratings
Frequency
50 ~ 60 Hz (
±
5 %)
Braking Circuit
Optional (Braking Unit, Resistor)
Max. Braking
Torque
Max. Continuous
Baking Time
Dynamic
Braking
4
Max. Duty
20%, Continuous
Weight [kg]
45
45
63
63
68
5
When applying input voltage of 507~528 V range, derate the load 10%. For example, when applying 507 V to 5.5kW inverters (rated
current 12A), the max. rated output current would be 10.8A, calculated by multiplying 12A by 0.9 (90%).
6
Same as above.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 [email protected]