The indoor unit installation
Installation Manual
21
ENGLISH
Wiring Connection
• Open the control box cover and connect the Remote controller cord and Indoor power wires.
• Remove the control box cover for electrical connection between the indoor and outdoor
unit. (Remove screws
①
.)
• Use the cord clamper to fix the cord.
Control box
Control box cover
(On which the Electric
Wiring Connection is put)
1
1
Control terminal board
Remote controler cord
Connection cord between the indoor
unit and the outdoor unit
Control terminal board
Control box
A
A
view
Remote
controler cord
Connection cord between the indoor
unit and the outdoor unit
Control box cover
(On which the Electric
Wiring Connection is put)
1
1
1
Control box cover
(On which the Electric
Wiring Connection is put)
Control box
Control terminal board
Remote controler cord
Connection cord between the indoor
unit and the outdoor unit
Ceiling Concealed Duct – Low Static, Mid Static
Ceiling Concealed Duct – H-INV
Ceiling Concealed Duct – High static
CAUTION
20 mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
The connecting cable
connected to the indoor and outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent. When the
connection line between the indoor unit and outdooor unit and outdoor unit is over 40 m, connect the telecommunication line and power line separately.
1,MFL67939921,영영 2018. 8. 2. 영영 1:41 Page 21