Troubleshooting Guide
Service Manual
105
16) Troubleshooting CH67, CH105
67
105
Outdoor fan
lock
Communication error
between main PCB and
fan PCB
• Outdoor fan is not oper-
ating
• Communication error
between main PCB
and fan PCB
• Check the fan condition.
• Check the fan connector
• Short or fusing of communication line
• Poor outdoor unit PCB
• Power input when the DC link capacitor discharges
Display
code
Title
Cause of error
Check point & Normal condition
Check Point
• CH 67
1. Check the install condition for fan.
• CH 105
1. Is communication line between the main PCB and the
fan PCB normal?
2. Is the communication LED on?