Head
77
⏐
GA10218_0101 - 5/2002
6.6.5.3 Calibration request
Main menu
>
Settings
>
Miscellaneous
>
Calibration request
It can be selected whether the operator is reminded of the fact that a cali-
bration may has become necessary or not. The default value is off.
If the calibration request is switched on, a corresponding message will
appear when 30 minutes have elapsed after power on or if the tempera-
ture of the PhoeniXL has changed by more than 5 °C (9 °F) since the last
calibration.
6.6.5.4 Service interval fore pump
Main menu
>
Settings
>
Miscellaneous
> Service interval fore pump
Setting for the service interval of the fore pump. This setting depends on
the use of the PhoeniXL but latest after 4000 running hours or one year
the oil in the pump should be controlled. See also manual for the Trivac
D2,5E which is included in the document folder. See chapter 9.1.1 also.
This setting is possible for the PhoeniXL
300
only.
6.6.5.5 Service interval exhaust oil filter
Main menu > Settings > Miscellaneous > Service Interval exhaust oil fil-
ter
Here you can enter the service intervall for the oil filter. This setting is only
possible for the PhoeniXL
300
. This setting depends on the use and appli-
cation of your PhoeniXL and therefor no recommendations can be given
(see 9.1.1).
Softkey 3: Off
The calibration request will be switched off.
Softkey 5: ?
Helptext
Softkey 7: ON
The calibration request will be switched on.
Softkey 3:
↓
The time for the service interval can be decreased in steps of 500 hours.
Softkey 7:
↑
The time for the service interval can be increased in steps of 500 hours to
the upper limit of 4000 hours.