90/102
17200234_002_C1/2016 - © Leybold
602494EA.DOCX
8
Dismounting and Storage
WARNING
Unqualified personnel
Inappropriate handling may cause serious injury or property damage.
Only qualified personnel are allowed to carry out the described work.
8.1
Dismounting
DANGER
Electric shock
Parts being under voltage will result in serious injury or death.
Disconnect the product from the mains.
1. Disconnect power supply.
2. Disconnect any connected tools, e.g. valve, pressur sensor, respectively from the
different connectors.
3. Loosen and remove four collar screws and plastic sleeves.
4. Withdraw the CMOVE 1250 from the 19" rack chassis.
8.2
Storage
NOTICE
Wrong storage
Inappropriate storage (static electricity, humidity etc.) can damage electronic
components.
Store product in antistatic bag or container. Observe the corresponding
specifications in chapter «1.4 Technical Data».