Autoreset ON
In any of the above cases, the CMOVE 1250 resumes pressure control under the
assumption that the current valve position is 0 (CLOSED).
Autoreset OFF
In any of the above cases, the CMOVE 1250 resumes pressure control by going back to the
position the valve was in before the condition occurred.
The «Configuration» display shows the current
settings of the operating mode, valve type, pressure
sensor, and nominal value (setpoint) with source
(I = internal, E = external). Press.
to get to the «General settings» display.
The «General settings» display shows the LCD
contrast, measurement unit of the pressure, language,
automatic booting and automatic reset function.
Press
5x
to edit the setting of the automatic reset
function.
to return to the «Configuration» display.
The Edit symbol is displayed in the «Autoreset» line.
Press
to set the automatic reset function to
on
or
off
.
to save the new setting and return to the
«Configuration» display.
GEN.
VALVE SENSOR I/O GEN.
Mode : Pressure
Valve : MOVE1250STD
Sensor: CTR1000T
Nom. I: 1.33E+01 mbar
Configuration
5×
General settings
LCD-Contrast : 30
Measure : mbar
Language : english
Autoboot : on
Autoreset : off
General settings
LCD-Contrast : 30
Measure : mbar
Language : english
Autoboot : on
Autoreset : off