| Monitoring the Switch
Displaying LLDP Information
– 276 –
Discovery services defined in this class include provision of
location identifier (including ECS / E911 information), embedded
L2 switch support, inventory management
◆
Capabilities
– The neighbor unit's LLDP-MED capabilities:
■
LLDP-MED capabilities
■
Network Policy
■
Location Identification
■
Extended Power via MDI - PSE
■
Extended Power vis MDI - PD
■
Inventory
■
Reserved
◆
Application Type
– The primary function of the application(s) defined
for this network policy, and advertised by an Endpoint or Network
Connectivity Device. The possible application types are described under
"Configuring LLDP-MED TLVs" on page 166
.
◆
Policy
– This field displays one of the following values:
■
Unknown: The network policy for the specified application type is
currently unknown.
■
Defined: The network policy is defined.
◆
Tag
– Indicates whether the specified application type is using a tagged
or an untagged VLAN.
◆
VLAN ID
– The VLAN identifier (VID) for the port as defined in IEEE
802.1Q-2003. A value of 1 through 4094 is used to define a valid VLAN
ID. A value of 0 (Priority Tagged) is used if the device is using priority
tagged frames as defined by IEEE 802.1Q-2003, meaning that only the
IEEE 802.1D priority level is significant and the default PVID of the
ingress port is used instead.
◆
Priority
– The Layer 2 priority to be used for the specified application
type. (Range: 0-7)
◆
DSCP
– The value to be used to provide Diffserv node behavior for the
specified application type as defined in IETF RFC 2474. (Range: 0-63)
◆
Location
– The physical location of the device attached to an interface,
including items such as the country, city, street number, building and
room information.
◆
Auto-negotiation
– Shows if MAC/PHY auto-negotiation is supported
by the link partner.
◆
Auto-negotiation Status
– Auto-negotiation status identifies if auto-
negotiation is currently enabled at the link partner. If Auto-negotiation
is supported and Auto-negotiation status is disabled, the 802.3 PMD
operating mode will be determined the operational MAU type field value
rather than by auto-negotiation.
Summary of Contents for GEL-2670
Page 1: ...GEL 2670 24 GE 2 GE SFP L2 Managed Switch User Manual Ver 1 0...
Page 2: ......
Page 4: ......
Page 6: ...ABOUT THIS GUIDE 6...
Page 18: ...FIGURES 18...
Page 20: ...TABLES 20...
Page 22: ...SECTION I Getting Started 22...
Page 34: ...SECTION II Web Configuration 34...
Page 46: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 46...
Page 224: ...CHAPTER 4 Configuring the Switch Configuring sFlow 224 Figure 95 sFlow Configuration...
Page 294: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 294...
Page 296: ...SECTION III Appendices 296...
Page 314: ...GLOSSARY 314...
Page 319: ......
Page 320: ...Level 1 GEL 2670 E012013 KS R01...