C
HAPTER
1
| Introduction
Description of Software Features
– 27 –
V
IRTUAL
LAN
S
The switch supports up to 4096 VLANs. A Virtual LAN is a collection of
network nodes that share the same collision domain regardless of their
physical location or connection point in the network. The switch supports
tagged VLANs based on the IEEE 802.1Q standard. Members of VLAN
groups can be manually assigned to a specific set of VLANs. This allows the
switch to restrict traffic to the VLAN groups to which a user has been
assigned. By segmenting your network into VLANs, you can:
◆
Eliminate broadcast storms which severely degrade performance in a
flat network.
◆
Simplify network management for node changes/moves by remotely
configuring VLAN membership for any port, rather than having to
manually change the network connection.
◆
Provide data security by restricting all traffic to the originating VLAN.
◆
Use private VLANs to restrict traffic to pass only between data ports
and the uplink ports, thereby isolating adjacent ports within the same
VLAN, and allowing you to limit the total number of VLANs that need to
be configured.
◆
Use protocol VLANs to restrict traffic to specified interfaces based on
protocol type.
IEEE 802.1Q
T
UNNELING
(Q
IN
Q)
This feature is designed for service providers carrying traffic for multiple
customers across their networks. QinQ tunneling is used to maintain
customer-specific VLAN and Layer 2 protocol configurations even when
different customers use the same internal VLAN IDs. This is accomplished
by inserting Service Provider VLAN (SPVLAN) tags into the customer’s
frames when they enter the service provider’s network, and then stripping
the tags when the frames leave the network.
T
RAFFIC
P
RIORITIZATION
This switch prioritizes each packet based on the required level of service,
using four priority queues with strict or Weighted Round Robin queuing. It
uses IEEE 802.1p and 802.1Q tags to prioritize incoming traffic based on
input from the end-station application. These functions can be used to
provide independent priorities for delay-sensitive data and best-effort data.
This switch also supports several common methods of prioritizing layer 3/4
traffic to meet application requirements. Traffic can be prioritized based on
the priority bits in the IP frame’s Type of Service (ToS) octet or the number
of the TCP/UDP port. When these services are enabled, the priorities are
mapped to a Class of Service value by the switch, and the traffic then sent
to the corresponding output queue.
Summary of Contents for GEL-2670
Page 1: ...GEL 2670 24 GE 2 GE SFP L2 Managed Switch User Manual Ver 1 0...
Page 2: ......
Page 4: ......
Page 6: ...ABOUT THIS GUIDE 6...
Page 18: ...FIGURES 18...
Page 20: ...TABLES 20...
Page 22: ...SECTION I Getting Started 22...
Page 34: ...SECTION II Web Configuration 34...
Page 46: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 46...
Page 224: ...CHAPTER 4 Configuring the Switch Configuring sFlow 224 Figure 95 sFlow Configuration...
Page 294: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 294...
Page 296: ...SECTION III Appendices 296...
Page 314: ...GLOSSARY 314...
Page 319: ......
Page 320: ...Level 1 GEL 2670 E012013 KS R01...