• In the operating mode without start- and restart-disable, the start input works as
activation input. As soon as a HIGH active signal is present at the start input (terminal
16) and the safety field is free, the safety outputs are closed.
A 24V suppy terminal (e.g. terminals 5, 10 or 11) can be used for the activation signal.
Figure 5.2-3:
Wiring of the start input "without start- and restart-disable"
+24V
Start
5 6
8
7
13 14 15 16
21 22 23 24
29 30 31 32
Sensor
Start/Active
EDM
OFF/ON
TNT35/7-24V
1 2
4
3
9 10 11 12