![Leuze electronic TNT 35 Connecting And Operating Instructions Download Page 70](http://html1.mh-extra.com/html/leuze-electronic/tnt-35/tnt-35_connecting-and-operating-instructions_1883986070.webp)
Applications
70
TNT 35 und TNT 35/7-24V
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
6.2
Example with a protective photoelectric sensor SLS 96 ...
Up to six pairs of SLS 96 protective photoelectric sensors can be connected in series
directly to the TNT 35. The supply of the protective photoelectric sensors comes directly
from the power supply of the installation/machine. Test monitoring of the photoelectric
sensors is carried out by the TNT 35.
Figure 6.2-1:
Connection diagram for a pair of SLS 96s
24
14
32
31
30
29
7
8
6
5
13
23
22
16
21
15
Start/
Active
Reset
GND
+24V
Active
TNT 35
}
Protective photo electric sensors
The operating mode is selected using a jumper
between:
terminal 22 & 23 (with start-/restart-disable)
or
terminal 23 & 24 (without start-/restart-disable)
EDM (relay monitoring, feedback circuit
Safety output 2
Safety output 1
Message output "Safety On"
Message output "Error"
}
Ope
ration
wi
th
star
t-/
and
resta
rt-d
isabl
e
Ope
rati
o
n
w
it
hout st
art-
/
and
resta
rt-d
isabl
e
Transmitter
Receiver
Emergency
shut-down