Function and Commissioning of TNT 35/7-24V
66
TNT 35 und TNT 35/7-24V
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
5.7
Technical Data
Safety-relevant technical data
Type in accordance with
IEC/EN 61496
Type 2
Performance Level (PL) in accor-
dance with ISO 13849-1: 2008
PL d
Category in accordance with
ISO 13849-1
Cat. 2
Average probability of a failure
to danger per hour (PFH
d
)
8.8 x 10
-8
1/h
Mean time to dangerous failure
(MTTF
d
)
69 years
Degree of cover DC
94%
Number of cycles until 10 % of
the components have a
failure to danger (B
10d
)
DC 13 - 24 V: 10 million switching cycles (2 A)
AC 15 - 230 V: 100,000 switching cycles (2 A)
600,000 switching cycles (1 A)
1.3 million switching cycles (0.5 A)
Service life (T
M
)
20 years
Electrical data
Supply voltage U
b
24V AC +15 %/-10 %
Frequency
50 Hz/60 Hz
Current consumption
approx. 200 mA
Response time
< 20 ms
Delay before start-up
approx. 2 s
Sensors
Transmitter activation
PNP (HIGH active)
Receiver input
optical coupler input,
input current approx. 10 mA
Sensor voltage supply
24V DC, max. 200 mA
In- and outputs
Start input
optical coupler input (High active)
input current approx. 10 mA
Reset input
optical coupler input (High active)
input current approx. 10 mA
Relay monitoring (EDM)
optical coupler input (High active)
input current approx. 10 mA