Function and Commissioning of the TNT 35
Leuze electronic
TNT 35 und TNT 35/7-24V
23
T
N
T
35/
7-
24V
DEUTSCH
ENGLISH
FRANÇAIS
IT
ALIANO
ESPAÑO
L
NEDERLANDS
Integration in a two-channel release circuit without relay monitoring
Both safety relay outputs are integrated seperately into the release circuits. These circuits
can be connected with additional components which trigger a common EMERGENCY
SHUT-DOWN device.
Note!
For the operating mode without relay monitoring, the jumper that short-circuits terminals 13
and 14
must
be set.
Figure 4.2-7:
Wiring safety output (two-channel release circuit)
5 6
8
7
13 14 15 16
21 22 23 24
29 30 31 32
Sensor
Start/Active
EDM
OFF/ON
TNT35
Release circuit 1
Release circuit 2