Function and Commissioning of the TNT 35
34
TNT 35 und TNT 35/7-24V
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
Safety field interruption:
The safety outputs of the TNT 35 are opened (LED "OFF/ON" on red) if during safety
operation the light beam of the protective photoelectric sensor is interrupted.
The restart-disable inside the TNT 35 becomes active and prevents an automatic restart of
the machine. The yellow LED "Start" displays the function of the restart-disable.
The TNT 35 is in waiting state and can be restarted by pressing the start-/restart button
after the safety field is free.
Figure 4.4-4:
Display of the TNT 35 during a safety field interruption