![Leuze electronic TNT 35 Connecting And Operating Instructions Download Page 71](http://html1.mh-extra.com/html/leuze-electronic/tnt-35/tnt-35_connecting-and-operating-instructions_1883986071.webp)
Applications
Leuze electronic
TNT 35 und TNT 35/7-24V
71
T
N
T
35/
7-
24V
DEUTSCH
ENGLISH
FRANÇAIS
IT
ALIANO
ESPAÑO
L
NEDERLANDS
6.3
Example with a protective light barrier ECO
Up to three pairs of protective photoelectric barriers of type ECO can be connected in
series directly to the TNT 35. The supply of the protective photoelectric barriers comes
directly from the power supply of the installation/machine. Test monitoring of the photoelec-
tric barriers is carried out by the TNT 35.
Figure 6.3-1:
Connection diagram for a pair of ECOs
24
14
32
31
30
29
7
8
6
5
13
23
22
16
21
15
Start/
Active
Reset
GND
+24V
TNT 35
}
Safety light barrier
The operating mode is selected using a jumper
between:
terminal 22 & 23 (with start-/restart-disable)
or
terminal 23 & 24 (without start-/restart-disable)
EDM (relay monitoring, feedback circuit
Safety output 2
Safety output 1
Message output "Safety On"
Message output "Error"
}
O
pera
ti
on w
it
h sta
rt-
/
a
nd r
e
start
-di
sabl
e
O
pera
ti
on w
it
hou
t star
t-/
a
nd r
e
start
-di
sabl
e
Test input
(PIN 4)
Transmitter
Receiver
Switching
output
(PIN 4)
Emergency
shut-down