Function and Commissioning of TNT 35/7-24V
Leuze electronic
TNT 35 und TNT 35/7-24V
47
T
N
T
35/
7-
24V
DEUTSCH
ENGLISH
FRANÇAIS
IT
ALIANO
ESPAÑO
L
NEDERLANDS
5.2.4
Wiring of single-beam protective photoelectric sensors
The activation input of the protective photoelectric sensor can be directly connected to
terminal 14 on the TNT 35/7-24V.
The switching output of the receiver can be directly connected to terminal 15.
The +24V supply for the safety sensors is taken from the supply terminals 5, 10 and 11, the
GND reference potential is taken from terminals 2, 3 and 6.
Figure 5.2-4:
Wiring of single-beam protective photoelectric sensors
5 6
8
7
13 14 15 16
21 22 23 24
29 30 31 32
Sensor
Start/Active
EDM
OFF/ON
TNT35/7-24V
1 2
4
3
9 10 11 12
17 1
8
19 20
GND
+24V
T
R
Active
GND
+24V