Function and Commissioning of TNT 35/7-24V
60
TNT 35 und TNT 35/7-24V
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
Safety field interruption:
The safety outputs of the TNT 35/7-24V are opened (LED "OFF/ON" on red) if during
safety operation the light beam of the protective photo electric sensor is interrupted.
The restart-disable inside the TNT 35/7-24V becomes active and prevents an automatic
restart of the machine. The yellow LED "Start" displays the function of the restart-disable.
The TNT 35/7-24V is in waiting state and can be restarted by pressing the start-/restart
button after the safety field is free.
Figure 5.4-4:
Display of the TNT 35/7-24V during a safety field interruption
5 6
8
7
13 14 15 16
21 22 23 24
29 30 31 32
Sensor
Start/Active
EDM
OFF/ON
TNT35/7-24V
1 2
4
3
9 10 11 12
17 1
8
19 20
Start
Activation
SLS