Mounting
Leuze electronic
RSL 410
56
Ensure that the response time of all components of the switch-off circuit are the same or balance the
response times with different protective field dimensioning.
Set the vertical protective fields at a slight angle so that the lower protective field edges protrude over
the vehicle width by the amount of the additional distances, Z
SM
, Z
F
and Z
REFL
where required; see
7.7
Mounting accessories
7.7.1 Mounting system
Using the mounting system you can adjust the safety sensor horizontally and vertically by ±10 degrees
when mounting.
Figure 7.17: Mounting system BTU800M
Install the wall mount or mounting bracket for floor mounting on the system side.
Mount the mounting system on the wall mount or on the mounting bracket for floor mounting.
Attach the safety sensor to the mounting system.
Tightening the screws fixes the safety sensor in position.
Align the safety sensor using the integrated electronic spirit level.
NOTICE
Floor mounting only with mounting system BTU800M
The mounting system BTU800M must be used in the case of installation using the mounting bracket
for floor mounting.