Configuration and diagnostic software Sensor Studio
Leuze electronic
RSL 410
26
4.5.5 DIAGNOSIS
Adjustment / Alignment
Display of safety sensor alignment using the integrated electronic spirit level
Prerequisites: The software and safety sensor are connected.
In the DIAGNOSIS menu, click the [Align sensor mechanically] button (
).
The safety sensor display shows the horizontal and vertical alignment in degrees.
Visually identify device
If you have installed multiple safety sensors, identify the safety sensor that is connected to the currently
open device manager (DTM).
Prerequisites: The software and safety sensor are connected.
In the DIAGNOSIS menu, click the [Visually identify sensor] button (
).
In the display of the safety sensor connected to the device manager (DTM), the message PING received
flashes for ten seconds.
Reset sensor
Acknowledge messages and faults
Set safety sensor to safety mode
Create and save service file
The service file contains all available information on the safety sensor as well as configuration and
settings.
When requesting support, send the service file to the Leuze electronic customer service (see chapter 14
"Service and support").
Sensor display
Device display in the DTM menu
• SENSOR DISPLAY
• STATE OF THE ACTIVE PROTECTIVE AND WARNING FIELDS
• SENSOR DATA
Diagnostics list
Access list
EventLog
4.5.6 SETTINGS
Communication
• LAN
• DHCP
• CONNECTION SETTINGS
• MAC address
• Bluetooth
• Activate Bluetooth module
• Activate device scan
• Bluetooth address
Data telegrams
A UDP telegram can be configured which sends the status profile of the safety sensor as well as the
measurement data to a receiving device connected via Ethernet, e.g. to a PC.
EventLog
Trigger signals output when certain events occur, are recorded and shown in the event list of the safety
sensor.
You can only transfer changes made in the SETTINGS menu to the safety sensor if you are
logged in with the access level
Engineer
.