Functions
Leuze electronic
RSL 410
29
Table 5.1:
Access levels and functions available
Determining access level
When creating a user in the user management via Tools > User management in the FDT frame menu,
select the access level for the user. In the user management you can also create and change passwords
for the users.
Using the device manager (DTM) you can change the access level of the user (see chapter 4.5.1
• Click in the DTM menu bar on the [Change access level] button (
).
5.2
Function modes of safety sensor
You configure the functions of the safety sensor in configuration projects with the help of the configuration
and diagnostics software. In each configuration project you determine the protective function and the
configurable field pairs via the selected function mode.
You select the function mode of the safety sensor in the software device manager (DTM) with
CONFIGURATION > OSSDs (see chapter 9 "Configuring the safety sensor").
You use the protective function to define the criteria for switching off the safety-related switching outputs
(see chapter 3.1.2 "Parameters for protective function").
The changeover-capable protective and warning field pairs for the selected function mode are defined in
the configuration banks, e.g. CONFIGURATION > Protective function A > Bank A1.
Access level
Functions
Observer
• Display the measurement contour
• Upload and display configuration data from the safety sensor
• Display status information from the safety sensor
• Display diagnostics list
• Customize display
• Display and evaluate the measurement contour
• Load configuration data from the safety sensor
• Load status information from the safety sensor
• Display diagnostics list
• Create service file
• Reset password
Expert
In addition to the functions of the
Observer
• Load the signed safety configuration from a file and transfer/download
to the safety sensor
• Transfer changed communication and diagnostics settings from the
PC to the safety sensor
• Print configuration data incl. protective/warning fields
• Calibrate optics cover
Engineer
In addition to the functions of the
Expert
, full access to all user-relevant
functions and parameters:
Create and change a safety configuration:
• Save configuration data to file
• Change all parameters of configuration
• Reset safety sensor to default values
• Define and change protective/warning fields
• Set reference contour in protective field
• Print and delete protective/warning fields
• Load protective/warning field data from file
• Save protective/warning field data
• Transfer protective/warning field data from the PC to the safety sensor
• Change passwords
The software saves individual passwords in the connected safety sensor, thereby ensuring that
only authorized users can change the existing configuration.