For error diagnostics, the error's respective letter is displayed first followed by the number code. An
AutoReset is carried out after 10 seconds for errors that do not cause locking, with an unauthorized restart
being impossible. In the case of blocking errors, the voltage supply must be separated and the cause of
the error must be eliminated. Before switching on again, the steps taken before initial commissioning must
be repeated (see chapter 10).
When the protective field has been free for about 5 seconds, the device switches back to the display in
normal operation.
Displays in normal operation
The display in normal operation depends on the operating state of the safety sensor. The display can be
switched off or rotated by 180° by means of the software.
3.3.3 Field-of-view display
The upper and lower limit of the safety sensor's field of view can be displayed by means of horizontal lines
on the optics cover.
Make sure that the safety sensor's field of view is always completely unobstructed.
3.4
Mounting system (optional)
Mounting systems and mounting brackets simplify mounting and alignment of the safety sensor. Mounting
systems and mounting brackets are available as accessories (see table 17.3).
3.5
Loop guard (optional)
The loop guard for the optics cover prevents damage to the safety sensor caused by light contact with
foreign objects. The loop guard is available as an accessory (see table 17.3).
Message via a signal output or diagnosis ID
ProtF A: E123
Device: P007 - wrong
Config
Fault diagnosis
F…
Failure, internal device error
E…
Error, external error
U…
Usage info, application error
I…
Information
P…
Parameter, inconsistency in the configuration
Display
Description
Example
NOTICE
Always check the protective field configuration!
Check all defined protective fields each time the configuration is changed.
The field-of-view display is a comfort function and is not intended as a substitute for checking the pro
-
tective field configuration.
The safety sensor's field of view must be completely unobstructed on the application side.