![Leuze electronic RSL 410 Operating Instructions Manual Download Page 100](http://html1.mh-extra.com/html/leuze-electronic/rsl-410/rsl-410_operating-instructions-manual_1884018100.webp)
Technical data
Leuze electronic
RSL 410
100
all dimensions in mm
The mounting plate BTU804MA supplements the old mounting system of the RS4/ROD4 for the
mounting system BTU800M.
Figure 15.14: Mounting plate BTU804MA
15.4 Representation of safety sensor status
The table lists all logic and electrical signals that are present in the safety sensor. The signal names are
used consistently throughout the configuration and diagnostics software (device DTM), in the event log
and in the data telegram.
Table 15.13:
Representation of status
192
166,3
157,5
5
1
,5
7
4
,4
9
0
9
0
,4
5°
2
2
,1
5
4
,5
Byte
Bit
Signal
Description
Value 0 Value T
Default
0
---
---
Type (variant) of status profile.
Extensions require new type of
status profile
---
---
1
1
---
OP-MODE
Operating mode:
• 1: Safety mode
• 2: Simulation mode
---
---
1
Messages and OSSDs