PROFINET
Leuze electronic
DCR 248i
86
Output data
Address
Data type
Value range
Default
Unit
Explanation
Reset Event
Counter
Switching
output 2
0.5
Bit
0 -> 1: Perform
reset
1 -> 0: No func-
tion
0
---
Sets the event counter
of the activation func-
tion [AF] for switching
output 2 back to zero.
Reset Event
Counter
Switching
output 3
0.6
Bit
0 -> 1: Perform
reset
1 -> 0: No func-
tion
0
---
Sets the event counter
of the activation func-
tion [AF] for switching
output 3 back to zero.
Reset Event
Counter
Switching
output 4
0.7
Bit
0 -> 1: Perform
reset
1 -> 0: No func-
tion
0
---
Sets the event counter
of the activation func-
tion [AF] for switching
output 4 back to zero.
Output data length: 1 byte