Technical data
Leuze electronic
DCR 248i
97
Tab. 15.4:
Environmental data
Ambient temp. (operation/stor-
age)
0 °C … +45 °C/-20 °C … +70 °C
Air humidity
max. 90% rel. humidity, non-condensing
Ambient light
Max. 2000 Lux
Electromagnetic compatibility
EN 61000-6-2, EN 61000-6-4
Vibration
IEC 60068-2-6, test Fc
Continuous shock
IEC 60068-2-29, test Eb
Certifications
UL 60950-1
CAN/CSA C22.2 No. 60950-1-07
CSA C22.2 No. 60950-1-07
Conformity
CE, FCC, UL
15.2
Optical data
Integrated LED illumination
Red light (visible, 616 nm)
Risk group 0 (exempt group)
Acc. to IEC 60825-1, EN 62471:2008
Integrated feedback LED
Green (528 nm)
Beam exit
Front
Image sensor
Global shutter CMOS Imager
Number of pixels
1280 x 960 pixels
Optics models
Resolution
• High Density (N)
0.127 mm (5 mil) … 0.25 mm (10 mil)
• Medium Density (M)
0.19 mm (7.5 mil) … 0.33 mm (13 mil)
• Low Density (F)
0.25 mm (10 mil) … 0.5 mm (20 mil)
Electronic shutter speeds
68 µs … 5 ms (flash)
15.2.1 Reading performance
Reading distance
see chapter 6.1.3 "Determining the reading distance"
Object speed
• N-optics: Up to 4 ms at m=0.19 mm (7.5 mil)
• M-optics: Up to 5 ms at m=0.25 mm (10 mil)
• F-optics: Up to 7 ms at m=0.33 mm (13 mil)
15.2.2 Code specifications
Code type: 1D
Code 128 EAN 128 (GS1-128), Code 39, Code 2/5 Interleaved, EAN 8/
EAN 13, UPC A/E, Pharmacode, Codabar (Monarch), Code 93
Code type: stacked
codes
GS1 DataBar (Omnidirectional, Expanded, Limted, Truncated)
GS1 DataBar (Stacked Omnidirectional, StackedExpanded)
PDF417
Code type: 2D
DataMatrix (ECC200), Aztec Code, GS1 Aztec Code, GS1 DataBar (ECC200)
QR-Code, GS1 QR-Code