PROFINET
Leuze electronic
DCR 248i
72
Tab. 10.16:
Input data structure module 101
Input data
Address
Data type
Value range
Default
Unit
Explanation
Data accep-
tance toggle
bit
0.0
Bit
0->1: Data have
been accepted
1->0: Data have
been accepted
0
---
The signal shows that
the device has ac-
cepted the data or the
data fragment.
Data rejec-
tion toggle bit
0.1
Bit
0->1: Data have
NOT been ac-
cepted
1->0: Data have
NOT been ac-
cepted
0
---
The device has re-
jected the acceptance
of the data or the data
fragment.
Reserved
0.2
Bit
0
---
Free
0.3
Bit
0
---
Free
Error code
0.4-0.7
Bit
0: No error
1: Receive buffer
overflow
2: Sequence er-
ror
3: Invalid length
entry
4: Invalid frag-
ment length entry
5: Length change
in a sequence
0
---
Cause of error for re-
jection of the fragment.
Input data length: 1 byte
Tab. 10.17:
Output data structure module 101
Output data
Address
Data type
Value range
Default
Unit
Explanation
Reserved
0.0
0
Free
0.1
0
Free
0.2
0
Free
0.3
0
---
Free
0.4
0
---
Free
New entry
0.5
Bit
0 -> 1: New entry
1 -> 0: New entry
0
---
The toggle bit shows
whether new entry data
is present
Reserved
0.6
Bit
0
---
Free
0.7
Bit
0
---
Free
Entry data
length
1
UN-
SIGNED16
0-65535
0
---
Data length of the ac-
tual information.
Data
3..10
8x
UN-
SIGNED8
0-FFh
0
---
Information with a
length of consistently
8 bytes.
Output data length: 3 bytes consis 8 bytes of result information