PROFINET
Leuze electronic
DCR 248i
60
Module
Description
Parameter
Inp. data
Outp.
data
M26
see chapter 10.4.10 "Re-
sult data 6"
Result data 6
Entry information 96 bytes max.
0
99
0
M27
see chapter 10.4.11 "Re-
sult data 7"
Result data 7
Entry information 128 bytes max.
0
131
0
M28
see chapter 10.4.12 "Re-
sult data 8"
Result data 8
Entry information 256 bytes max.
0
259
0
M101 –
see chapter 10.4.13 "Entry
data 1"
Entry data 1
Entry information 8 bytes max.
0
1
11
M102
see chapter 10.4.14 "Entry
data 2"
Entry data 2
Entry information 16 bytes max.
0
1
19
M103
see chapter 10.4.15 "Entry
data 3"
Entry data 3
Entry information 32 bytes max.
0
1
35
M104
see chapter 10.4.16 "Entry
data 4"
Entry data 4
Entry information 48 bytes max.
0
1
51
M105
see chapter 10.4.17 "Entry
data 5"
Entry data 5
Entry information 64 bytes max.
0
1
67
M106
see chapter 10.4.18 "Entry
data 6"
Entry data 6
Entry information 96 bytes max.
0
1
99
M107
see chapter 10.4.19 "Entry
data 7"
Entry data 7
Entry information 128 bytes max.
0
1
131
M108
see chapter 10.4.20 "Entry
data 8"
Entry data 8
Entry information 256 bytes max.
0
1
259
M60
see chapter 10.4.21 "De-
vice status and control"
Device status and control
Display of the device status as well
as control bits for reset and standby
0
1
1
M61
see chapter 10.4.22 "De-
vice application status and
control"
Device application status and con-
trol
Transfer of application-specific con-
trol and status information.
0
2
2
M74
see chapter 10.4.23 "I/O
status and control"
I/O status and control
Handling of switching input and
switching output signals
0
2
1