PROFINET
Leuze electronic
DCR 248i
71
Tab. 10.15:
Input data structure module 28
Input data
Address
Data type
Value range
Default
Unit
Explanation
Activation
status
0.0
Bit
0: Deactivated
1: Activated
0
---
Displays the current
activation status.
Reserved
0.1
Bit
0
---
Free
User data re-
sult or Cmd
interpreter re-
sponse
0.2
Bit
0: User data
1: Cmd inter-
preter response
0
---
Distinction between re-
sult from the Formatter
and answer from the
Cmd interpreter.
Makes the distinction
easy for the user.
Further re-
sults in the
buffer
0.3
Bit
0: No
1: Yes
0
---
Signal indicates
whether further results
are in the buffer.
Buffer over-
flow
0.4
Bit
0: No
1: Yes
0
---
Signal indicates that
result buffer is occu-
pied and the device re-
jects data.
New result
0.5
Bit
0->1: New result
1->0: New result
0
---
The toggle bit indicates
whether a new result is
present.
Reserved
0.6
Bit
0
---
Free
Waiting for
acknowledg-
ment
0.7
Bit
0: Base state
1: Control waiting
for acknowledge-
ment from the
master
0
---
This signal represents
the internal state of the
control.
Result data
length
1
UN-
SIGNED 16
0-65535
0
---
Data length of the ac-
tual result information.
Data
3..258
256x
UN-
SIGNED8
0-FFh
0
---
Result information with
a length of consistently
256 bytes.
Input data length: 3 bytes consis 256 bytes of result information
10.4.13 Module 101 – Entry data 1
PROFINET-IO module identifier
• Module ID: 1101
• Submodule ID: 1
NOTICE
Ä
Data reset does
not
affect the output data toggle bits
Ä
If fragmentation is used, the application must set the output data of the entry data fragmen-
tation module for each fragment that is to be transmitted before the toggle bit is toggled in
the entry data module (see chapter 10.4.4 "Module 16 – Fragmented entry").
Description
The module defines the transfer of entry data to a command interpreter (Cmd interpreter) in the device.