PROFINET
Leuze electronic
DCR 248i
63
10.4.4 Module 16 – Fragmented entry
PROFINET-IO module identifier
• Module ID: 1016
• Submodule ID: 1
Description
The module defines the transfer of fragmented entry data (direction: from control to device). To occupy few
I/O data, the entry data may be split into several fragments with this module. The fragments can then be
transmitted one after another with a handshake.
These settings act on entry modules 101 … 108. The presence of this module switches on fragmentation of
the entry data.
Tab. 10.6:
Parameter overview module 16
Parameter
Address
Data type
Value range
Default
Unit
Explanation
Fragment
length
0
UN-
SIGNED8
1-255
1
---
The parameter defines
the maximum length of
the entry information
per fragment.
Parameter length: 1 byte
Tab. 10.7:
Output data structure module 16
Output data
Address
Data type
Value range
Default
Unit
Explanation
Fragment
number
0
Byte
0-255
0
---
Current fragment num-
ber
Remaining
fragments
1
Byte
0-255
0
---
Number of fragments
which still have to be
transmitted for a com-
plete entry.
Fragment
size
2
UN-
SIGNED8
0-255
0
---
Fragment length,
should always be iden-
tical, except for the last
fragment to be trans-
ferred.
Output data length: 3 bytes, consistently
10.4.5 Module 21 – Result data 1
PROFINET-IO module identifier
• Module ID: 1021
• Submodule ID: 1
NOTICE
Ä
Modules 21 … 28 can only be used one at a time, not simultaneously.
Ä
If the result information (result plus additional information, such as the code quality) does not
fit in the selected module width, the information is shortened.
The transmitted result data length is an indication of shortening of the result information.
Description
The module defines the transfer of the result data. The result data comes from the Formatter currently se-
lected. The Formatter can be selected and configured in the webConfig tool (see chapter 9.3 "webConfig
tool").