PROFINET
Leuze electronic
DCR 248i
85
Input data
Address
Data type
Value range
Default
Unit
Explanation
Switching
output 3
Comparison
state toggle
bit
(Event
Counter)
1.5
Bit
0->1: Event
counter ex-
ceeded
1->0: Event
counter ex-
ceeded again
0
---
If SWOUT switches
several times was con-
figured as comparison
mode, this bit is tog-
gled each time the
event counter is ex-
ceeded.
The bit is reset to the
initial value by resetting
the event counter.
Comparison
state switch-
ing output 4
(Event
Counter)
1.6
Bit
0: Not exceeded
1: Exceeded
0
---
Indicates whether the
event counter has ex-
ceeded the set com-
parative value.
The bit is reset to the
initial value by resetting
the event counter.
Switching
output 4
Comparison
state toggle
bit
(Event
Counter)
1.7
Bit
0->1: Event
counter ex-
ceeded
1->0: Event
counter ex-
ceeded again
0
---
If SWOUT switches
several times was con-
figured as comparison
mode, this bit is tog-
gled each time the
event counter is ex-
ceeded.
The bit is reset to the
initial value by resetting
the event counter.
Input data length: 2 bytes
Tab. 10.37:
Output data structure module 74
Output data
Address
Data type
Value range
Default
Unit
Explanation
Switching
output 1
0.0
Bit
0: Switching out-
put 0
1: Switching out-
put 1
0
---
Sets the state of
switching output 1
Switching
output 2
0.1
Bit
0: Switching out-
put 0
1: Switching out-
put 1
0
---
Sets the state of
switching output 2
Switching
output 3
0.2
Bit
0: Switching out-
put 0
1: Switching out-
put 1
0
---
Sets the state of
switching output 3
Switching
output 4
0.3
Bit
0: Switching out-
put 0
1: Switching out-
put 1
0
---
Sets the state of
switching output 4
Reset Event
Counter
Switching
output 1
0.4
Bit
0 -> 1: Perform
reset
1 -> 0: No func-
tion
0
---
Sets the event counter
of the activation func-
tion [AF] for switching
output 1 back to zero.