Mounting
Leuze electronic
DCR 248i
26
1D-Codes
2D-Codes
400
[mm]
350
300
250
200
150
100
50
0
0.127 mm (5 mil)
0.19 mm (7.5mil)
0.25 mm (10 mil)
0.5 mm (20 mil)
0.127 mm (5 mil)
0.19 mm (7.5 mil)
0.25 mm (10 mil)
0.5 mm (20 mil)
1
1
Reading distance [mm]
Fig. 6.2:
Typical reading distances for 1D- and 2D-codes with various modulus sizes of the codes
Reading distances for code reader with M1-optics
NOTICE
Please note that the actual reading distances are also influenced by factors such as labeling
material, printing quality, reading angle, printing contrast etc., and may thus deviate from the
reading distances specified here.
1D-Codes
2D-Codes
400
[mm]
350
300
250
200
150
100
50
0
0.19 mm (7.5 mil)
0.25 mm (10 mil)
0.35 mm (14 mil)
0.5 mm (20 mil)
0.19 mm (7.5 mil)
0.25 mm (10 mil)
0.35 mm (14 mil)
0.5 mm (20 mil)
1
1
Reading distance [mm]
Fig. 6.3:
Typical reading distances for 1D- and 2D-codes with various modulus sizes of the codes