Commissioning – Leuze electronic webConfig tool
Leuze electronic
DCR 248i
51
9.3.1
Change operating mode
For configurations with the webConfig tool, you can switch between the following operating modes:
•
Process
The device is connected to the control or to the PC.
• The process communication to the control is activated.
• The switching inputs/outputs are activated.
• The image currently recorded by the code reader is displayed if the function was not deactivated in
the webConfig tool.
• The configuration cannot be changed.
•
Service
• Process communication to the control or to the PC has been interrupted.
• The switching inputs/outputs are deactivated.
• The configuration can be changed.
NOTICE
Configuration changes only in the
Service
operating mode!
Ä
Changes made using the
CONFIGURATION
function can only be performed in the
Service
operating mode.
Located in the upper left of all pages of the webConfig tool is a software switch for changing the operating
mode (
Process
-
Service
).
After changing to the
Service
operating mode, the
CONFIGURATION
menu is displayed.
1
1
Changing the operating mode (
Process
-
Service
)
Fig. 9.2:
CONFIGURATION
menu of the webConfig tool
9.3.2
Menu options of the webConfig tool
The webConfig tool offers the following menu functions:
•
PROCESS
• Information on the current read result
• Current camera image
• Status of the switching inputs/outputs
• Reading statistics