PROFINET
Leuze electronic
DCR 248i
75
Input data
Address
Data type
Value range
Default
Unit
Explanation
Error code
0.4-0.7
Bit
0: No error
1: Receive buffer
overflow
2: Sequence er-
ror
3: Invalid length
entry
4: Invalid frag-
ment length entry
5: Length change
in a sequence
0
---
Cause of error for re-
jection of the fragment.
Input data length: 1 byte
Tab. 10.21:
Output data structure module 103
Output data
Address
Data type
Value range
Default
Unit
Explanation
Reserved
0.0
0
Free
0.1
0
Free
0.2
0
Free
0.3
0
---
Free
0.4
0
---
Free
New entry
0.5
Bit
0 -> 1: New entry
1 -> 0: New entry
0
---
The toggle bit shows
whether new entry data
is present
Reserved
0.6
Bit
0
---
Free
0.7
Bit
0
---
Free
Entry data
length
1
UN-
SIGNED16
0-65535
0
---
Data length of the ac-
tual information.
Data
3..34
32x
UN-
SIGNED8
0-FFh
0
---
Information with a
length of consistently
32 bytes.
Output data length: 3 bytes consis 32 bytes of result information
10.4.16 Module 104 – Entry data 4
PROFINET-IO module identifier
• Module ID: 1104
• Submodule ID: 1
NOTICE
Ä
Data reset does
not
affect the output data toggle bits
Ä
If fragmentation is used, the application must set the output data of the entry data fragmen-
tation module for each fragment that is to be transmitted before the toggle bit is toggled in
the entry data module (see chapter 10.4.4 "Module 16 – Fragmented entry").
Description
The module defines the transfer of entry data to a command interpreter (Cmd interpreter) in the device.