Technical data
Leuze electronic
CML 720i Ex
126
Table 16.5:
Data on the time behavior of the CML 720i Ex
Table 16.6:
Electrical data
Table 16.7:
CML 720i Ex open-circuit current
Table 16.8:
CML 720i Ex measurement field length and explosion protection
Table 16.9:
Interface data
Response time per beam
a)
30 µs
Readiness delay
≤ 1.5 s
a) Cycle time = number of beams x 0.03 ms + 0.4 ms. The minimum cycle time is 1 ms.
Operating voltage U
B
18 … 30 VDC (incl. residual ripple)
Residual ripple
≤ 15% within the limits of U
B
Measurement field length
[mm]
Current consumption [mA] (without load at switching output)
at U
B
24 VDC
at U
B
18 VDC
at U
B
30 VDC
150
135
165
125
310
165
200
145
630
215
275
190
950
270
345
235
1430
350
455
300
1910
435
650
365
2870
600
780
500
Measurement field length
Explosion protection
130 mm to 2550 mm
Zone 2 (gas), zone 22 (dust)
2630 mm to 2950 mm
Zone 22 (dust)
Inputs/outputs
2 pins can be configured as input or output
Switching output current
Max. 100 mA
Signal voltage active/not active
≥ 8 V / ≤ 2 V
Activation delay
≤ 1 ms
Input resistance
Approx. 6 k Ω
Digital interfaces
IO-Link (230.4 kbit/s; 38.4 kbit/s)
CANopen (max. 1 Mbit/s)