11.2.3 Configuration of area/output mapping via CANopen interface
Map the beams to output pin 2 as follows.
11.3 Example configuration - Hole recognition
The following table shows an example configuration for hole recognition for web material with signaling of
a hole at output pin 2. Example of detection beginning with a free beam with fixed/dynamic web position.
First activate and configure a beam area (e.g., area 01).
Map the area to the corresponding switching output.
Digital IO Pin 2 Settings
(group 10)
Index 80, bit offset 24:
= 0
Pin 2 as output
Index 80, bit offset 16:
= 1
Switching behavior inverted
Index 80, bit offset 0:
= 1
Switching output area 32 … 1
Index 84, bit offset 0:
= 1
Bit mapping of area 01 to pin 2
Configuration of area 01
(module 8)
Index 0x2170 sub 01:
= 1
Area 01 active
Index 0x2170 sub 02:
= 0
Light switching
Index 0x2170 sub 03
= 1
Start beam of the area
Index 0x2170 sub 04:
= 32
End beam of the area
Index 0x2170 sub 05:
= 32
Number of active beams for area ON
Index 0x2170 sub 06:
= 31
Number of active beams for area OFF
Switching level of inputs/out
-
puts
(module 7)
Index 0x2151 sub 01:
= 0
Pin 2 as output
Index 0x2151 sub 03:
= 1
Switching behavior inverted
Index 0x2151 sub 04:
= 1
Switching output area 32 … 1
Index 0x2155 sub 03:
= 1
Bit mapping of area 01 to pin 2
Description / variables
Configuration of area 01
Area
Value: 1 = active
01
This area is active and is then mapped to output pin 2.
Logical behavior of the area
Value: 0 = normal - light switching
00
Switching in case of free beams.
Start beam of the area
Value: FIB for dynamic web position or fixed position
value, if specified
FIB
If a hole is to be detected in a web with arbitrary position or width, the value
FIB is to be set for the start beam.
With fixed position value, the start beam of the area is to be set.
End beam of the area
Value: LIB for dynamic web position or fixed position
value, if specified
LIB
If a hole is to be detected in a web with arbitrary position or width, the value LIB
is to be set for the end beam.
With fixed position value, the end beam of the area is to be set.
Number of active beams for area ON
Value: 1
1
With this setting, the area (output) switches as soon as one or more beams are
not interrupted.
Number of active beams for area OFF
Value: 0
0
Description / variables
Configuration of pin 2
Input/output selection
Value: 0 = output
Pin 2 functions as digital output
Function of the switching output
Value: 1 = switching output area 1 … 32
The switching output signals the logical states of beam
areas 1 … 32
Switching behavior
Switching behavior
Value: 0 = normal - light switching
Value: 1 = inverted - dark switching
Configuration according to the necessary switching