Starting up the device - CANopen interface
Leuze electronic
CML 720i Ex
92
End beam of the area
2170
4
t16U
RW
1
FFFE
1
1 … 1774
65534: First interrupted beam
(FIB)
65533: First not interrupted
beam (FNIB)
65532: Last interrupted beam
(LIB)
65531: Last not interrupted
beam (LNIB)
Number of active beams for area ON
2170
5
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Number of active beams for area OFF
2170
6
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Specified middle of the area
2170
7
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Specified width of the area
2170
8
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Configuration of area 2
2171
Area
2171
1
t08U
RW
0
1
0
0: Not active
1: Active
Logical behavior of the area
2171
2
t08U
RW
0
1
0
0: Normal - light switching
1: Inverted - dark switching
Start beam of the area
2171
3
t16U
RW
1
FFFE
1
1 … 1774
65534: First interrupted beam
(FIB)
65533: First not interrupted
beam (FNIB)
65532: Last interrupted beam
(LIB)
65531: Last not interrupted
beam (LNIB)
End beam of the area
2171
4
t16U
RW
1
FFFE
1
1 … 1774
65534: First interrupted beam
(FIB)
65533: First not interrupted
beam (FNIB)
65532: Last interrupted beam
(LIB)
65531: Last not interrupted
beam (LNIB)
Number of active beams for area ON
2171
5
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Number of active beams for area OFF
2171
6
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Specified middle of the area
2171
7
t16U
RW
0
MAX_BEA
M
0
0 … 1774
Specified width of the area
2171
8
t16U
RW
0
MAX_BEA
M
0
0 … 1774
All other 30 areas are configured in the same way as described for 2170 and 2171:
Configuration of area 3
2172
Configuration of area 4
2173
Configuration of area 5
2174
Configuration of area 6
2175
Configuration of area 7
2176
Configuration of area 8
2177
Configuration of area 9
2178
Configuration of area 10
2179
Parameter
Index
(hex.)
Sub-
index
(hex.)
Data
type
Access
Min.
value
Max. value Default Explanation