Starting up the device - Basic configuration
Leuze electronic
CML 720i Ex
62
Select Digital IOs > IO Logic > Positive PNP.
Select Digital IOs > IO Pin 2 > IO Function > Area Output.
Select Digital IOs > IO Pin 2 > Inversion > Inverted.
Select Digital IOs > IO Pin 2 > Area Logic > OR.
Select Digital IOs > IO Pin 2 > Start Beam > 001.
Select Digital IOs > IO Pin 2 > End Beam > 032.
Configuration of pin 2 as PNP warning output
The following example shows the configuration of pin 2 as PNP warning output.
Select Digital IOs > IO Logic > Positive PNP.
Select Digital IOs > IO Pin 2 > IO Function > Warn Out.
Configuration of pin 2 as PNP trigger input
The following example shows the configuration of pin 2 as PNP trigger input.
Select Digital IOs > IO Logic > Positive PNP.
Select Digital IOs > IO Pin 2 > IO Function > Trigger In.
A teach input is configured according to the same principle.
Start Beam
001
End beam
032
Level 0
Level 1
Level 2
Description
Level 0
Level 1
Level 2
Description
Digital IOs
IO Logic
Positive PNP
Negative NPN
IO Pin 2
IO Function
Trigger input
Teach input
Area output
Warning output
Trigger output
Inversion
Normal
Inverted
Teach height
Execute
Exit
Area logic
AND
OR
Start beam
(enter value)
End beam
(enter value)
Level 0
Level 1
Level 2
Description
Digital IOs
IO Logic
Positive PNP
Negative NPN
IO Pin 2
IO Function
Trigger input
Teach input
Area output
Warning output
Trigger output
Inversion
Normal
Inverted
Teach height
Execute
Exit
Area logic
AND
OR
Start beam
(enter value)
End beam
(enter value)
Trigger input and output are only active if cascading (triggered operation) was activated via the
configuration interface or process interface.