1
M12 plug (8-pin, A-coded)
2
M12 plug (5-pin, A-coded)
Figure 7.6: X1/X3 connection
Table 7.2:
X1/X3 pin assignment – CML 720i Ex with CANopen or IO-Link interface
Connection cables: see table 17.3, see table 17.7
Pin assignment on the short end of the Y-interconnection cable (PWR IN/digital IO)
5-pin, M12 plug (A-coded) on the short end of the Y-interconnection cable for connecting to PWR IN/
digital IO.
1
M12 plug (5-pin, A-coded)
Figure 7.7: X1 connection - PWR IN/digital IO
Table 7.3:
X1 pin assignment - PWR IN/digital IO
1
2
Pin (X1) X1 - Logic and power on the receiver and connection to transmitter
Pin (X3)
1
VIN: +24 V DC supply voltage
2
2
IO 1: input/output (configurable)
3
GND: ground (0 V)
3
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
6
RS 485 Tx-: synchronization
5
7
RS 485 Tx+: synchronization
4
8
SHD: FE functional earth, shield
1
1
PWR IN/Digital IO
Pin
X1 - Short end of the Y-interconnection cable
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Ex works: teach input