Diagnostics and troubleshooting
Leuze electronic
BPS 348i
85
Table 10.2:
PWR LED displays – causes and measures
10.3 Error messages on the display
Via the optional display of the BPS, the device outputs the following possible error status information while
it has the
BPS Info
device status:
•
System OK
BPS operating error-free.
•
Warning
Warning message. Here, it is useful to query the device status with PROFINET module 6.
•
Error
Device function is not ensured.
Figure 10.2: Example: Device status/error status information on the display
10.4 Checklist for causes of errors
Table 10.3:
Service interface errors – causes and measures
Error
Possible cause
Measures
Off
• No supply voltage connected
to the device
• Hardware error
• Check supply voltage
• Contact Leuze electronic customer ser
-
vice(see chapter 12 „Service and
support“)
Red, flashing
• No bar code in the scanning
beam
• No valid measurement value
• Query BCB diagnostic data and carry out
the resulting measures (see table 10.6)
Red, continuous light
• Error: No function possible
• Internal device error
• Determine the cause of the device error
using the event log of the webConfig
diagnostics
• Contact Leuze electronic customer ser
-
vice(see chapter 12 „Service and
support“)
Orange, continuous
light
• Device in
Service
mode
• Reset the device to
Process
mode using
the webConfig tool
BPS Info
System OK
Error
Possible cause
Measures
webConfig does not
start
• Incorrect connection cable
• Connected BPS is not recog
-
nized
• No communication via USB ser
-
vice interface
• Check connection cable
• Install USB driver