PROFINET interface – basic configuration
Leuze electronic
BPS 348i
65
8.6.13 Module 11 – Static velocity limit value 1
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Velocity resolution
0.0 …
0.2
Bit
0 … 1
1
mm
/s
(in/
100)
/s
Resolution for the velocity value:
001 = 1: 1
010 = 2: 10
011 = 3: 100
100 = 4: 1000
101 = 5: Free resolution
Averaging
0.3 …
0.5
Bit
0 … 1
2
-------------
All calculated velocities are averaged over the speci
-
fied time:
000 = 0: No averaging
001 = 1: 2 ms
010 = 2: 4 ms
011 = 3: 8 ms
100 = 4: 16 ms
101 = 5: 32 ms
Input data
Rel.
Adr.
Data type Value range
Init-
Value
Measure
-
ment unit
Description
metr. Inch
Velocity
0
sign
32 bit
-1.000.000 …
+1.000.000
0
scaled
Current velocity.
Module ID: 1011 or submodule ID: 1
The module provides all parameters for the Static velocity limit value 1 function.
This function compares the current velocity with a limit velocity stored via the configuration. The
comparison takes place in the configured range, which is defined by the
Range start
and
Range
end
parameters.
If a direction-dependent limit value check is activated via the
Direction selection
parameter, the
values of the
Range start
and
Range end
parameters also define the direction. The check is al
-
ways performed from range start to range end.
Example: If the range start is
5500
and the range end is
5000
, the direction-dependent check is
only performed in the direction from
5500
to
5000
. The limit value is not active in the opposite
direction.
If the check is independent of direction, the order of range start and range end is irrelevant. De
-
pending on the selected switching mode, if the value is above or below the defined limits, the limit
value status in module 16 (see chapter 8.6.18) is set and, if configured, the switching output is
appropriately set via module 4 (see chapter 8.6.6) or module 5 ( see chapter 8.6.7).
If the range start is identical to the range end, a continuous, direction-independent limit value
check is performed.
The module contains parameters (with parameter data length of 13 bytes), but no input data and
no output data.