PROFINET interface – basic configuration
Leuze electronic
BPS 348i
63
8.6.10 Module 8 – Position limit value range 2
8.6.11 Module 9 – Error handling procedures
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Lower pos. limit 1
0 … 3
sign
32 bit
-10.000.000 …
+10.000.000
0
mm
in/
100
Lower position limit.
Upper pos. limit 1
4 … 7
sign
32 bit
-10.000.000 …
+10.000.000
0
mm
in/
100
Upper position limit.
Module ID: 1008 or submodule ID: 1
The module defines a distance range with lower and upper limits. If the measured position value
is outside of the configured range, the corresponding status bit is set in module 6 and, if config
-
ured, an output is set.
The module contains parameters (with parameter data length of 8 bytes), but no input data and
no output data.
Parameter
Rel.
Adr.
Data type Value range
De
-
fault
Measure
-
ment unit
Description
metr. Inch
Lower pos. limit 2
0 … 3
sign
32 bit
-10.000.000 …
+10.000.000
0
mm
in/
100
Lower position limit.
Upper pos. limit 2
4 … 7
sign
32 bit
-10.000.000 …
+10.000.000
0
mm
in/
100
Upper position limit.
Module ID: 1009 or submodule ID: 1
The module makes parameters available to handle any errors should they occur.
If there is a brief disturbance in the position value or the velocity calculation in the device, the
BPS sends the last valid measurement value for a configured time.
If the BPS can again calculate valid measurement values within the error delay time, these are
output. The disturbance is made evident only as a small increase in the output measurement val
-
ue.
If the problem with the calculation lasts for a longer period of time, it is possible to configure how
the BPS is to behave.
The module contains parameters (with parameter data length of 8 bytes), but no input data and
no output data.