Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 348i
73
9
Leuze electronic webConfig tool – Extended configuration
With the Leuze electronic webConfig tool, an operating-system independent, web-technology based,
graphical user interface is available for configuring the BPS.
The webConfig tool can be run on any Internet-ready PC. The webConfig tool uses HTTP as communica
-
tion protocol and the client-side restriction to standard technologies (HTML, JavaScript and AJAX) that are
supported by modern browsers.
9.1
Installing the required software
In order for the BPS to be automatically detected by the connected PC, the USB driver must be installed
once on your PC. Administrator rights are required for driver installation.
9.1.1 System requirements
The webConfig tool is offered in the following languages:
German, English, French, Italian, Spanish
NOTICE
Configuration changes via the webConfig tool have no effect in PROFINET!
Always perform the basic configuration using the GSDML file (see chapter 8 „PROFINET interface –
basic configuration“).
In process operation, only the parameters in the PROFINET modules set via the GSDML file or the
PROFINET default presets are in effect. Parameter changes made via the webConfig tool are no lon
-
ger in effect on the PROFINET.
The parameters for the timing of the switching inputs/outputs can only be adjusted with the webConfig
tool.
If you switch the BPS to the
Service
operating mode via the webConfig tool, the BPS is disconnected
from the PROFINET. All parameters set via the GSDML file initially remain in effect. Parameter chang
-
es can now be made via the webConfig tool for test purposes.
Settings configured with the webConfig tool are overwritten by the PROFINET master with the settings
made via the GSDML file upon connection to PROFINET or after deactivation of the
Service
operating
mode. Settings that cannot be configured via PROFINET, e.g., timing functions, are not overwritten.
NOTICE
BPS configuration via webConfig tool
The webConfig tool displays no PROFINET parameters.
The configuration data is saved in the device and in the connection hood.
If a USB driver for the webConfig tool is already installed on your computer, the USB driver does
not need to be installed again.
Regularly update the operating system and the Internet browser.
Install the current Windows Service Packs.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]