![Leuze electronic BPS 348i Manual Download Page 76](http://html1.mh-extra.com/html/leuze-electronic/bps-348i/bps-348i_manual_1883982076.webp)
Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 348i
77
Overview of the webConfig configuration functions
Figure 9.2:
CONFIGURATION
webConfig function
Configuration of the switching inputs/outputs (
DEVICE
tab)
• Definition: Switching input or switching output *
• Event output *
• Function input *
• Inversion yes/no *
• Debounce time **
• Switch-on/switch-off delay **
• Signal delay **
• Pulse duration **
webConfig configuration parameters
*: PROFINET parameter, see chapter 8.6
**: Parameter can only be configured via webConfig
NOTICE
Start-up configuration of the switching inputs and outputs!
The configuration for switching inputs and outputs SWIO 1 and SWIO 2 is generally performed via the
GSDML file.
The settings configured with the webConfig tool that differ from the GSDML configuration are overwrit
-
ten on start-up by the PROFINET master with the settings made via the GSDML file. Settings that can
-
not be configured via PROFINET, e.g., timing functions, are not overwritten.
PROFINET modules 4 and 5 configure switching inputs and outputs (I/Os) SWIO 1 and SWIO 2 (see
chapter 8.6.6 and see chapter 8.6.7), e.g.,
whether SWIO 1 and SWIO 2 operate as input or output
which events act on the output
the function of the input
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]