Technical data
Teachware 8400 - Application case (2-axis) - DOC 80100005 - DE EN 04.2020
19
EN
2.
Technical data
2.1.
Scope of supply
Position Number Name
1
1x
Teachware (incl. removable trolley, grips and case lid with pocket for accessories, 24 V / 5 A DC power supply for
encoder supply (can be switched on and off via toggle switch) and 24 V sockets on the front panel, 24 V / 0.6 A DC
power supply unit for brake supply in the MCS motor (can be switched on and off via toggle switch), 2x K 1.6 A line
circuit breaker, 2x T5/620 x 10 mm toothed belt drive with protective cover)
2
1x
Inverter Drives 8400 StateLine 0,25 kW, 230 V AC (mounted)
3
1x
Inverter Drives 8400 HighLine 0,25 kW, 230 V AC (mounted)
4
1x
Inverter Drives 8400 TopLine 0,25 kW, 230 V AC (mounted)
5
1x
AC asynchronous motor SDSGAIG056-22 (mounted)
6
1x
Servo synchronous brake motor MCS 06C41-RS0P1-B11N-ST5S00N-R1SU (mounted)
7
1x
Sick-Stegmann Hiperface multiturn absolute value encoder SEL52-HNA0-K02, Art. 1037373 with connection cable
(mounted)
•
Number of sine /Cosine periods per revolution: 16
•
Maximum overall measurable number of revolutions: 4096
8
1x
Keypad
X400 EZAEBK1001
9
1x
USB diagnostics adapter with connection cable (2.5 m)
10
4x
Single cable with 4 mm laboratory plugs black (1.5 m)
11
2x
Single cable with 4 mm laboratory plugs yellow (1.5 m)
12
2x
Single cable with 4 mm laboratory plugs green (1.5 m)
13
2x
Switching system IO with foil-applier 8400 and connection cable (mounted at Inverter Drives 8400)
14
1x
Accessories (optional)
•
3x Sick-Stegmann inductive sensor Type IME12-02BPSZW2K, No. 1040733, 24 V, 0 - 2000 Hz, switching distance:
2 mm (2x with mounting flange for measurement of belt speed, 1x for measurement the belt pulley speed)
•
1x Toothed belt T5/750 x 10 mm to wrap the 4 toothed belt pulleys
•
2x Toothed belt pulley 21 T5 / 36-2 for the realization of transmissions
2x Motor plate + Makrolon protection cover for realization of further applications, see 3.6
15
1x
Manual DE/EN
2.2.
Standards and operating conditions
Conformity
CE
2014/35/EU
Low-Voltage Directive
2014/30/EU
EMC Directive
RoHS
2011/65/EU
Restrictions for the use of specific hazardous materials in electric and electron-
ic devices
Protection of persons and device protection
Enclosure
EN 60529
IP20
NEMA 250
only protection against accidental contact acc. to type 1
Contact current
EN 60204-1
< 10 mA AC and DC
Control circuit isolation
EN 61800-5-1
Safe mains isolation by double/reinforced insulation
Total fault current
EN 61800-5-1
In TN power systems, it is permissible to use the following residual current
circuit breakers: 30 mA, type F, B, or B+
Insulation resistance
EN 61800-5-1
Site altitude
0 … 2000 m
a.m.s.l.
Overvoltage category III
above 2000 m a.m.s.l.
Overvoltage category II
Cyclic mains switching
Cyclic mains switching of max. 3 times in 1 minute is permissible without re-
strictions
Supply conditions
Mains system
TN, TT
Voltage against earth: max. 300 V
IT
Not permitted
Voltage deviations
EN 50160
-
15 % … + 10 %