Motor control (MCTRL)
Selection of the operating mode
88
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
Selection and parameter setting of the motor
A. Select the motor from the »Engineer« motor catalogue.
Continue with step
• If the Lenze motor is not listed there, continue with step
.
• If you use an external motor, continue with
• then
B. Prepare the motor parameter identification by setting the following data taken from
the motor nameplate:
• Rated motor power
• Rated motor frequency
• Motor cos
ϕ
C. Carry out motor parameter identification
The following parameters are identified and automatically transmitted to the
corresponding codes:
• Motor leakage inductance
• Mutual motor inductance
• Stator resistance (total resistance from motor cable resistance and stator
resistance)
D. Enter the nameplate data and the equivalent circuit data of the external motor:
• Rated motor power
• Rated motor frequency
• Motor cos
ϕ
• Stator resistance
• Stator inductance
• Leakage inductance
The field-oriented sensorless vector control is now ready for operation.