Firmware 03.00 - DMS EN 5.0 - 07/2009
L
217
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00833
C00833
C00909
Parameter | Name:
C00833 | 8Bit-Input
Data type: UNSIGNED_8
Index: 23742
d
= 5CBE
h
From version 03.00.00
Display of the signal status of the binary inputs of different blocks
Selection list
0 False
1 True
Subcodes
Info
C00833/1
L_NSet_1: bRfg0
C00833/2
L_NSet_1: bNSetInv
C00833/3
L_NSet_1: bJog1
C00833/4
L_NSet_1: bJog2
C00833/5
LS_SetError_1: bSetError1
C00833/6
LS_SetError_1: bSetError2
C00833/7
L_MPot_1: bUp
C00833/8
L_MPot_1: bInAct
C00833/9
L_MPot_1: bDown
C00833/10
L_MPot_1: bEnable
C00833/11
Reserved
C00833/12
L_PCTRL_1: bIOff
C00833/13
L_PCTRL_1: bEnableInfluenceRamp
C00833/14
LS_DCTRL: bCINH
C00833/15
LS_DCTRL: bFailReset
C00833/16
LS_DCTRL: bStatus_B0
C00833/17
LS_DCTRL: bStatus_B2
C00833/18
LS_DCTRL: bStatus_B3
C00833/19
LS_DCTRL: bStatus_B4
C00833/20
LS_DCTRL: bStatus_B5
C00833/21
LS_DCTRL: bStatus_B14
C00833/22
LS_DCTRL: bStatus_B15
C00833/23
L_RLQ_1: bCw
C00833/24
L_RLQ_1: bCcw
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00909 | Speed limitation
Data type: INTEGER_16
Index: 23666
d
= 5C72
h
Maximum positive/negative speed for all operating modes
Setting range
(min. value | unit | max. value)
0.0
%
175.0
Subcodes
Lenze setting
Info
C00909/1
120.0 %
Max. pos. speed
C00909/2
120.0 %
Max. neg. speed
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100