8400 BaseLine D | Software Manual
Function library
Function blocks
146
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
9
Function library
9.1
Function blocks
9.1.1
L_NSet
This FB is used for general signal processing of process values and is provided with the
following functions:
Ramp function generator with linear ramps for main setpoint path
Setting and holding the ramp function generator
S-shaped ramp (PT1 rounding) of the ramp function generator
Internal limitation of the input signal
3 fixed setpoints (JOG setpoints)
Inputs
Outputs
Identifier/data type
Information/possible settings
bRfg0
BOOL
Leading the main setpoint integrator to 0 within the current Ti times
True The current value of the mains setpoint integrator is led to "0" via the
Ti time set.
bNSetInv
BOOL
Signal inversion for the main setpoint
True Main setpoint signal is inverted.
nNSet_a
INT
Main setpoint signal
• Other signals are also permitted
bJog1 ... bJog2
BOOL
Selection inputs for fixed change-over setpoints (JOG setpoints) for the main
setpoint
• Selection inputs are binary coded.
Identifier/data type
Value/meaning
nNOut_a
INT
Speed setpoint output signal
• 16384
≡
100 %
bRfgIEqO
BOOL
Status signal "ramp function generator has reached setpoint"
True The ramp function generator has reached the speed setpoint.
DMUX
bRfgStop
bRfg0
bNSetInv
nNSet_a
bJog2
CINH
JOG 0...3
bJog1
L_NSet
/1
/2
/3
1
C134
C182
C012
C013
bRfgIEq0
±
32767
nNOut_a
0
1
0
3
C039