8400 BaseLine D | Software Manual
Drive control (DCTRL)
Parameter setting
66
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
4.4.3
Handling of the memory module
In the delivery state, the Lenze setting of the parameters is stored in the memory module.
The following cases are distinguished regarding the handling:
• Delivery
– All devices are delivered with a plugged-on memory module.
– The memory module is available as a spare part - without any data.
• During operation
– The memory module (EPM) is required for operation.
– Parameter sets can be saved manually.
– Parameter sets can be loaded manually
• Replacement of the controller
If the controller has to be replaced, observe the versions of the devices. Generally, the
following applies:
– Before the data is transferred, the version is checked.
– Parameter sets of devices with V 1.0 can be processed on devices
≥
V 1.0
(downward compatibility).
– If the parameter set versions of the two devices are not compatible, an error message
(PS02/PS03, see
) is generated.
– Parameters of a higher device version are not supported on devices with a lower
version.
Danger!
If the memory module has been removed and the device is switched on, the
connector pins are live and thus dangerous since the protection against contact
is missing.
Stop!
The memory module must not be plugged in or unplugged during operation.
Note!
• Automatic saving is explicitly not supported because this significantly
reduces the service life of the memory module.
• The 8400 BaseLine memory module is not compatible with the 8400
StateLine and 8400 HighLine memory modules.
• If the memory module has been removed, the "PS01" error message appears,
see