8400 BaseLine D | Software Manual
Drive Application
Overview of the software structure of the drive application function
136
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
8.1
Overview of the software structure of the drive application function
[8-1]
Software structure of the application function
The device comes integrated with the drive application ("actuating drive - speed"). This
drive application provides the main signal flow for implementing a general or particular
drive task in the form of a signal interconnection of diverse function blocks (application
level).
The drive application is provided with an input interface for connecting the control signal
sources (e.g. main setpoint) and an interface for controlling the device outputs.
The control signals and device outputs are connected to the drive application in the I/O
level.
Within the drive application, the main setpoint path affects the signals for the motor
control and the state control of the controller.
Both the control inputs and the control outputs and the entire drive application are
provided with parameters for
Setting / parameter setting of internal functions
Display of actual values
Connection of the FBs in the I/O level
All these parameters can be addressed via the diagnostic interface. The parameters are set
e.g. via the internal keypad or diagnostics / user interfaces in the »Engineer«.
STOP
M
M
0
1
n
t
è
ç
8888
B
ESC
C
D
E
F
A
X4
GND
A1U
DI1
DI2
DI3
DI4
X4
24E
DO1
X101
NO
COM
Signal
inputs
Motion
Drive
control
Motor
control
Signal
outputs
Setpoint
generator
Parameterisation
Parameterisation