6
Installation and Operation
EDBC250SIO | 2.0
66
FSoE parameter
Parameter
Unit
Range
[Default]
Description / note
FSoE address
-
1 ... 65535
[1]
FSoE slave address set at DIP switch
Connection ID
-
1 ... 65535
[1]
Unique ID of the connection to a FSoE slave
WatchdogTime
ms
20 … 65534 (FFFE
h
)
[100]
Watchdog time of FSoE frame
Used Inputs
Dec
0 .... 15
[15]
Enables the inputs used
Selection from a drop-down list depends on the configurator
Binary
Decimal
Active Inputs
0
0
0
0
0
No inputs used
0
0
0
1
1
Input 0
0
0
1
0
2
Input 1
0
0
1
1
3
Inputs 0,1
0
1
0
0
4
Input 2
0
1
0
1
5
Inputs 0,2
0
1
1
0
6
Inputs 1,2
0
1
1
1
7
Inputs 0,1,2
1
0
0
0
8
Input 3
1
0
0
1
9
Inputs 0,3
1
0
1
0
10
Inputs 1,3
1
0
1
1
11
Inputs 0,1,3
1
1
0
0
12
Inputs 2,3
1
1
0
1
13
Inputs 0,2,3
1
1
1
0
14
Inputs 1,2,3
1
1
1
1
15
Inputs 0,1,2,3
External Inputs
Dec
Bits 0-3
0000
2
.... 1111
2
[0000
2
]
Disables the generation of the module's test pulses if the sensors connected
generate their own test pulses (OSSD) at the outputs or, optionally, for
operation without test pulses (OSSD) and disables special functions rotary
switch and pressure-sensitive mat.
Test pulse outputs, bits 0-3
0 test pulse output is used
1 test pulse output is not used (external test pulses enabled)
Bits 4,5
00
2
… 11
2
[00
2
]
Mode selector, bits 4 and 5
00 disabled
01 2 channels (inputs 0 & 1)
10 3 channels (inputs 0 - 2)
11 4 channels (inputs 0 – 3)