6
Installation and Operation
EDBC250SIO | 2.0
57
NOTE
Lay the feed lines of pressure-sensitive mats and bumpers together
In order to avoid influences and malfunctions due to EMC effects, lay the four
wires (e.g. SI0, SI0 TP, SI1, SI1 TP) together.
CAUTION
"Short circuit in mat" fault is not detected
The Safety I/O-module fails to detect a short circuit between the mat contacts.
This is interpreted as the mat being actuated. You must also verify that the
safeguard is wired correctly.
Periodically check that the mat is working properly.
CAUTION
Safety function pressure-sensitive mat requires a response time of 50 ms
Avoid personal injury and damage to property
The pressure-sensitive mat function achieves a response time of 50 ms
between a change in mat state and providing the information on the
EtherCAT bus.
I