Server model: twenty 2.5-inch SAS/SATA drives, one 8i RAID adapter, one 16i RAID adapter
Notes:
• Ensure that all cables are routed through the correct cable clips.
• Broken lines indicate the hidden parts.
Figure 22. Cable routing for server models with twenty 2.5-inch SAS/SATA drives, one 8i RAID adapter and one 16i RAID
adapter
Cable
From
To
1
SAS signal cable for
backplane 1
SAS 0 and SAS 1 connectors on
backplane 1
C0 and C1 connectors on the 16i RAID
adapter
2
SAS signal cable for
backplane 2
SAS 0 and SAS 1 connectors on
backplane 2
C2 and C3 connectors on the 16i RAID
adapter
3
Power cable for backplane 1
Power connector on backplane 1
Backplane 1 power connector on the
system board
4
Power cable for backplane 2
Power connector on backplane 2
Backplane 2 power connector on the
system board
42